• Vapor Phase Drying Equipment-Vpd
  • Vapor Phase Drying Equipment-Vpd
  • Vapor Phase Drying Equipment-Vpd
  • Vapor Phase Drying Equipment-Vpd

Vapor Phase Drying Equipment-Vpd

V: 182.25m3
Usable Length: 8500mm
Usable Width: 4000mm
Usable Height (From Top Surface of Troll: 3850mm
Leakage Rate: 5mbar
Total Power: 500kw; 3 Phases
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
VPD-300
AC
380-440V, 50Hz
Air Compressor
0.6m3/Min
Pressure
5~8 Bar
Water Temperature
28
Transport Package
Standard Packing
Specification
9.0 4.5 4.5
Trademark
Senerge
Origin
Zhejiang
Production Capacity
30 Sets/Month

Product Description

Vapor Phase Drying Equipment
    SPECIFICATION
          
CONTENT
 

VPD-300 INNER TYPE KEROSENE VAPOR PHASE DRYING PLANT
 
1 ,Vacuum drying plant
 
1,Tank inner size: 9.0×4.5×4.5(L×W×H)  V=182.25M3
Effective dimensions of a chamber (m):8.5×4.0×4.0(L×W×H)
Main materials: hot rolled steel plate and hot rolled section steel
   Heating pipe will be used material of STGP-35-joint-less steel and being considered , as welding structure.
2,Tank shape: horizontal
As a tunnel type of a horizontal form, the rail for carts is laid inside.
3,The temperature in tank is controlled automatically; and the highest temperature is : 135±5ºC
4,The temperature difference at random two points after heating and preserving is : ≤±5ºC
5,The ultimate vacuum degree in the cool tank is : ≤ 6Pa
6,Leakage Rate : 5mbar.L/S
7,Ultimate working vacuum degree : ≤30Pa
8,The airproof structure of the tank mouth is adopted the lip shaped rubber ring which is high temperature resistant.  
9,Observing window, lighting, electrode down-lead; two watching windows.(more than φ300mm size) from the ceiling outside.
10,.The opening and closing mode of the tank door: hydraulic locking and unlocking, moving side.
11,The Pt100 platinum resistances are adopted for measuring the temperature in the tank, and there are  6 measuring points in the tank.
12,The heating mode: electric heater(heating medium is thermal oil)
13,Inside of the autoclave is painted polyurethane which resists heat and solvent.
2,Hydraulic system for door opening;
Door moving mechanics
 
For lock and unlock of the tank door
Include 1 Hydraulic unit, 4 cylinders and connecting tubes. Vertical decelerator and moving mechanism.
Moving direction of the doors:Right and left
3 ,Connection bridge unit To improve automation
1 set cylinder
unit for bridge turn over
4,The trolley
 
The transformer is loaded into autoclave by trolley, there are double rails on the ground for moving trolley (the rails should be made by buyer), the surface of rails should be same level as ground; and there are same double rails in the autoclave for supporting the trolley;
Outside size:8.5×4.0×0.5(m) 
Than Weight of Load :200ton
5,Vacuum system
 
The system includes : 2 stages Roots pumps: WH7000/ WAU2001
(Leybold, Germany); max. pumping speed is 9800m³/h.
4 sets rotary vane pump: SV300B(Leybold, Germany)
2 stages vacuum condenser, valves and pipelines.
The ultimate vacuum degree of the unit: P0<1Pa
The suction capacity of the unit: 9800m³/h
2,the main suction valves adopt DN250 pneumatic butterfly valves. (made in NJ, Shanghai)

3,DN300 middle condenser
                                           
4,The vacuum gauge DISPLAY ONE adopted is made in Leybold, Germany
  1. Two-digit mantissa in the range form 5×10-4 to1×103 mbar
  2. Readout selectable between mbar, Torr or Pascal
  3. 0 to 10V chart recorder output via plug-in screw terminals.

5,Accessorial parts ( see detail list) include:
   Manual ball valves, pneumatic butterfly valves, ripple pipes(stainless steel), vacuum gauge and pipes corresponded.

6, There is an exhaust separator before backing pumps.
6,The kerosene evaporating and condensate feeding  system
 
  1. The inner cascade evaporator is installed on one side of the drying tank inner. It transforms the kerosene into steam.
The evaporating power: 300KW
  1. The kerosene condensed flows through the buffering tank, the motor shielded pump, 10μm paper core fine filter, then goes into the inner cascade kerosene evaporator, and becomes kerosene steam again.
  2. The impurity grain contained in the filtered kerosene is small to 10μm..
  3. The dimension of the buffering tank is DN1600×2000(straight portion)
  4. 2 sets of kerosene feeding pumps made by Empire motor shielded pump Co.,Ltd., Dalian( Japanese sole proprietorship)
  5. Type: F81-216J4BM-0405S1-F; Working temperature: 155ºC
Working medium: keroseneγ=0.78 Q=6M3/h H=28M N=2.2KW
  1. 6,DN300 heat exchanger of surplus heat    
  2. 7,DN80 magnetic filter                                             
  3. 8,10μm Fine magnetic filter                           
  4. 9,Accessorial parts( see detail list) include :
  5. Manual/pneumatic ball valves, all kinds of instruments and gauges and corresponding pipes etc.
7 ,The condensing and reclaiming system of the kerosene steam
 
1,the mixed steam of kerosene and water expelled from the tank flow through the main condenser, and be separated in the collecting tank made of stainless steel.
2,The working vacuum degree of this system is 25-45mbar
3,300KW main condenser                         
4 ,Dimension of the collecting tank: Φ1.0×1.0m(stainless steel)                                
5,Tuning fork location limited switch : LS-YC-T-1           
6,Thermocouples for measuring the temperature.
7,Heat exchanger of waste heat                           
8,Accessorial parts( see detail list) include :
Manual/pneumatic ball valves, all kinds of instruments and gauges and corresponding pipes etc.  